- 主页 >
- 支持 >
- V-SFT Ver.6版本更新内容
V-SFT Ver.6版本更新内容
V-SFT Ver.6的升级记录
OCT 2026 Ver. 6.2.12.0
- V10 series SYS PROG:version V1.800, OS:version V1.90
V9 series SYS PROG:version V3.700, OS:version V5.10
TS2000 series SYS PROG:version V2.470
TS1000Smart series SYS PROG:version V2.470
V8 series SYS PROG:version V2.390
JUN 2026 Ver. 6.2.11.0a
- V10 series SYS PROG:version V1.700, OS:version V1.80
V9 series SYS PROG:version V3.600, OS:version V5.00
TS2000 series SYS PROG:version V2.470
TS1000Smart series SYS PROG:version V2.470
V8 series SYS PROG:version V2.390
APR 2026 Ver. 6.2.11.0
- V10 series SYS PROG:version V1.700, OS:version V1.80
V9 series SYS PROG:version V3.600, OS:version V5.00
TS2000 series SYS PROG:version V2.470
TS1000Smart series SYS PROG:version V2.470
V8 series SYS PROG:version V2.390
DEC 2025 Ver. 6.2.10.0
- V10 series SYS PROG:version V1.600, OS:version V1.70
V9 series SYS PROG:version V3.500, OS:version V5.00
TS2000 series SYS PROG:version V2.450
TS1000Smart series SYS PROG:version V2.450
TS1000 series SYS PROG:version V2.450
V8 series SYS PROG:version V2.390
OCT 2025 Ver. 6.2.9.0
- V10 series SYS PROG:version V1.500, OS:version V1.60
V9 series SYS PROG:version V3.400, OS:version V5.00
TS2000 series SYS PROG:version V2.450
TS1000Smart series SYS PROG:version V2.450
TS1000 series SYS PROG:version V2.450
V8 series SYS PROG:version V2.390
OCT 2025 Ver. 6.2.8.0
- V10 series SYS PROG:version V1.500, OS:version V1.60
V9 series SYS PROG:version V3.300, OS:version V5.00
TS2000 series SYS PROG:version V2.450
TS1000Smart series SYS PROG:version V2.450
TS1000 series SYS PROG:version V2.450
V8 series SYS PROG:version V2.390
JUN 2025 Ver. 6.2.7.0
- V10 series SYS PROG:version V1.400, OS:version V1.50
V9 series SYS PROG:version V3.200, OS:version V5.00
TS2000 series SYS PROG:version V2.450
TS1000Smart series SYS PROG:version V2.450
TS1000 series SYS PROG:version V2.450
V8 series SYS PROG:version V2.390
APR 2025 Ver. 6.2.6.0
- V10 series SYS PROG:version V1.400, OS:version V1.50
V9 series SYS PROG:version V3.200, OS:version V5.00
TS2000 series SYS PROG:version V2.450
TS1000Smart series SYS PROG:version V2.450
TS1000 series SYS PROG:version V2.450
V8 series SYS PROG:version V2.390
DEC 2024 Ver. 6.2.5.0
- V10 series SYS PROG:version V1.300, OS:version V1.40
V9 series SYS PROG:version V3.100, OS:version V4.90
TS2000 series SYS PROG:version V2.440
TS1000Smart series SYS PROG:version V2.440
TS1000 series SYS PROG:version V2.440
V8 series SYS PROG:version V2.390
X1/V10/V9/TS/V8 series: 追加PLC梯形图传送功能:
- Fuji Electric MICREX-SX SPH2200 supported.
- Fuji Electric MICREX-SX SPH3300 supported.
OCT 2024 Ver. 6.2.4.0a
- V10 series SYS PROG:version V1.300, OS:version V1.40
V9 series SYS PROG:version V3.100, OS:version V4.90
TS2000 series SYS PROG:version V2.440
TS1000Smart series SYS PROG:version V2.440
TS1000 series SYS PROG:version V2.440
V8 series SYS PROG:version V2.390
OCT 2024 Ver. 6.2.4.0
- V10 series SYS PROG:version V1.300, OS:version V1.40
V9 series SYS PROG:version V3.100, OS:version V4.90
TS2000 series SYS PROG:version V2.440
TS1000Smart series SYS PROG:version V2.440
TS1000 series SYS PROG:version V2.440
V8 series SYS PROG:version V2.390
APR 2024 Ver. 6.2.3.0
- V10 series SYS PROG:version V1.200, OS:version V1.30
V9 series SYS PROG:version V3.000, OS:version V4.90
TS2000 series SYS PROG:version V2.440
TS1000Smart series SYS PROG:version V2.440
TS1000 series SYS PROG:version V2.440
V8 series SYS PROG:version V2.390
OCT 2023 Ver. 6.2.2.0
- V10 series SYS PROG:version V1.100, OS:version V1.10
V9 series SYS PROG:version V2.900, OS:version V4.80
TS2000 series SYS PROG:version V2.430
TS1000Smart series SYS PROG:version V2.430
TS1000 series SYS PROG:version V2.430
V8 series SYS PROG:version V2.390
JUN 2023 Ver. 6.2.1.0
- V10 series SYS PROG:version V1.000, OS:version V1.00
V9 series SYS PROG:version V2.800, OS:version V4.80
TS2000 series SYS PROG:version V2.420
TS1000Smart series SYS PROG:version V2.420
TS1000 series SYS PROG:version V2.420
V8 series SYS PROG:version V2.390
APR 2023 Ver. 6.2.0.0
- V10 series SYS PROG:version V1.000, OS:version V1.00
V9 series SYS PROG:version V2.800, OS:version V4.80
TS2000 series SYS PROG:version V2.420
TS1000Smart series SYS PROG:version V2.420
TS1000 series SYS PROG:version V2.420
V8 series SYS PROG:version V2.390
DEC 2022 Ver. 6.1.8.0
- V9 series SYS PROG:version V2.700, OS:version V4.70
TS2000 series SYS PROG:version V2.390
TS1000Smart series SYS PROG:version V2.390
TS1000 series SYS PROG:version V2.390
V8 series SYS PROG:version V2.390
OCT 2022 Ver. 6.1.7.0
- V9 series SYS PROG:version V2.600, OS:version V4.60
TS2000 series SYS PROG:version V2.390
TS1000Smart series SYS PROG:version V2.390
TS1000 series SYS PROG:version V2.390
V8 series SYS PROG:version V2.390
- TS2060(i)-U20x supported.
APR 2022 Ver. 6.1.6.0a
- V9 series SYS PROG:version V2.600, OS:version V4.40
TS2000 series SYS PROG:version V2.390
TS1000Smart series SYS PROG:version V2.390
TS1000 series SYS PROG:version V2.390
V8 series SYS PROG:version V2.390
APR 2022 Ver. 6.1.6.0
- V9 series SYS PROG:version V2.600, OS:version V4.40
TS2000 series SYS PROG:version V2.390
TS1000Smart series SYS PROG:version V2.390
TS1000 series SYS PROG:version V2.390
V8 series SYS PROG:version V2.390
NOV 2021 Ver. 6.1.5.0
- V9 series SYS PROG:version V2.500, OS:version V4.30
TS2000 series SYS PROG:version V2.390
TS1000Smart series SYS PROG:version V2.390
TS1000 series SYS PROG:version V2.390
V8 series SYS PROG:version V2.390
OCT 2021 Ver. 6.1.4.0
- V9 series SYS PROG:version V2.500, OS:version V4.30
TS2000 series SYS PROG:version V2.380
TS1000Smart series SYS PROG:version V2.380
TS1000 series SYS PROG:version V2.380
V8 series SYS PROG:version V2.380
- V9 series: Products without serial communication CPU for Siemens MPI/PPI supported.
OCT 2021 Ver. 6.1.3.0
- V9 series SYS PROG:version V2.400, OS:version V4.20
TS2000 series SYS PROG:version V2.380
TS1000Smart series SYS PROG:version V2.380
TS1000 series SYS PROG:version V2.380
V8 series SYS PROG:version V2.380
MAY 2021 Ver. 6.1.2.0
- V9 series SYS PROG:version V2.300, OS:version V4.10
TS2000 series SYS PROG:version V2.360
TS1000Smart series SYS PROG:version V2.360
TS1000 series SYS PROG:version V2.360
V8 series SYS PROG:version V2.360
APR 2021 Ver. 6.1.1.0
- V9 series SYS PROG:version V2.300, OS:version V4.10
TS2000 series SYS PROG:version V2.360
TS1000Smart series SYS PROG:version V2.360
TS1000 series SYS PROG:version V2.360
V8 series SYS PROG:version V2.360
DEC 2020 Ver. 6.1.0.0
- V9 series SYS PROG:version V2.200, OS:version V4.00
TS2000 series SYS PROG:version V2.340
TS1000Smart series SYS PROG:version V2.340
TS1000 series SYS PROG:version V2.340
V8 series SYS PROG:version V2.340
- X1 series (X115 and X112) added to Edit Model.
- X1 series: Vector Graphics supported.
- X1 series: Application Alignment supported.
- X1 series: OPC UA (Server and Client) supported.
- X1 series: MQTT (Microsoft Azure) supported.
- X1 series: Web Browser supported.
- V-SFT-6: Failure fixed.
OCT 2020 Ver. 6.0.39.0
- V9 series SYS PROG:version V2.200, OS:version V4.00
V8 series SYS PROG:version V2.340
TS2000 series SYS PROG:version V2.340
TS1000 series SYS PROG:version V2.340
TS1000Smart series SYS PROG:version V2.340
-
V9/TS/V8 series: 追加PLC梯形图传送功能:
- OMRON CP series supported.
- Siemens S7-1200/1500 Tag(Ethernet ISOTCP) supported.
- Siemens LOGO! (Ethernet ISOTCP) supported.
- FATEK AUTOMATION FACON FBs series (Ethernet) supported.
- Hitachi Industrial Equipment Systems SJ Series P1(MODBUS RTU) supported.
- CIMON CP3E supported.
- General AE-LINK supported.
-
V9/TS series: 追加PLC梯形图传送功能:
- Panasonic LP-RF series supported.
- Panasonic LP-RF series (Ethernet) supported.
-
V9 series: Printer type added. *1
- HP printers supporting HPLIP version up to 3.18.6. *2
- EPSON EP-712A
- V9 series: Local screen: Changes in local screen specifications.
- V9 series: Local screen: Expansion I/O test screen
- V9 series: USB camera: Extended information output device feature.
- V9/TS series: Screen program transfer (write) is allowed only to the V9/TS with a specific MAC address.
- TS series: Main menu screen: Improved signal level display for communication parameters.
- V-SFT-6: BECKHOFF Tag ADS Protocol (Ethernet TCP/IP) Extended function.
- V-SFT-6: Password protection function is supported when sending and receiving screen program data.
- V-SFT-6: Trend: Extended logging word count.
- V-SFT-6: Password lock function when editing a screen program.
- V-SFT-6: Multi Language Batch Copy: Extended feature
- V-SFT-6: Additional parts: New panel meters with dials of 90 or 270 degrees
- V-SFT-6: Tag Database: Extended specifications
*1 OS upgrade is required.
*2 Supported by V9 hardware ver. f or later.
JUL 2020 Ver. 6.0.38.0
- V9 series SYS PROG:version V2.150, OS:version V3.90
TS2000 series SYS PROG:version V2.320
TS1000Smart series SYS PROG:version V2.320
TS1000 series SYS PROG:version V2.320
V8 series SYS PROG:version V2.320
-
V9/TS/V8 series: 追加PLC梯形图传送功能:
- KEYENCE KV-8000 (Ethernet TCP/IP) supported.
-
V9/TS/V8 series: KEYENCE UG device memory (buffer memory of expansion unit) supported.
- KV-3000/5000
- KV-3000/5000(Ethernet TCP/IP)
- KV-7000/8000(Ethernet TCP/IP)
- KV-Nano
- KV-Nano(Ethernet TCP/IP)
- V9 series: Printing data sheets: Line-spacing setting supported.
- V-SFT-6: KEYENCE XYM display of PLC device memory supported.
APR 2020 Ver. 6.0.37.0
- V9 series SYS PROG:version V2.100, OS:version V3.90
V8 series SYS PROG:version V2.320
TS2000 series SYS PROG:version V2.320
TS1000 series SYS PROG:version V2.320
TS1000Smart series SYS PROG:version V2.320
APR 2020 Ver. 6.0.36.0
- V9 series SYS PROG:version V2.100, OS:version V3.90
V8 series SYS PROG:version V2.320
TS2000 series SYS PROG:version V2.320
TS1000 series SYS PROG:version V2.320
TS1000Smart series SYS PROG:version V2.320
-
V9 series: 追加PLC梯形图传送功能:
- 3S-Smart Software Solutions CODESYS V3 (Ethernet) supported. *
- MITSUBISHI ELECTRIC QnU series (Multi CPU) (Built-in Ethernet) supported.
- Additional accessory: V-I/O (serial extension I/O) supported.
-
V9/TS/V8 series: 追加PLC梯形图传送功能:
- OMRON EJ1 supported.
- KEYENCE KV Nano supported.
- KEYENCE KV Nano (Ethernet TCP/IP) supported.
- KEYENCE DL-RS1A (SK-1000) supported.
- BECKHOFF Tag ADS Protocol (Ethernet) supported.
- CIMON XP supported.
- Gammaflux G24 (Ethernet TCP/IP) supported.
- SAIA PCD: The range of supported station number was extended.
- Modbus slave (TCP/IP): Multiple settings allowed for PLC2 through PLC8.
- V9 series: VNC server: function extended. *
- V9 series: Operation log: function extended. *
- V9 series: Data sheet printing - PDF output: function extended. *
- V9 series: USB camera: Macro commands to stop/start event record function supported.
- V9 series: RESTART macro command: additional features
- V9 series: Additional system devices: various version information
- V9 series: PLC ladder monitor OMRON C series supported.(C200H/C200HX only)
- V-SFT-6: Tag import: Siemens TIA Portal Ver.15.1/16 supported.
- V-SFT-6: Additional parts library
- V-SFT-6: Parts: Flipping image supported.
- V-SFT-6: Font setting: comment feature supported.
- V-SFT-6: Additional auto-resizing feature
- V-SFT-6: Table data display: additional feature
- V-SFT-6: Additional confirmation window
- V-SFT-6: Project view: additional feature
- V-SFT-6: Screen list: additional feature
- DVD: The upgrade version of V-SFT-5 is bundled to the V-SFT-6 DVD.
*OS upgrading required.
NOV 2019 Ver. 6.0.35.0
- V9 series SYS PROG:version V2.000, OS:version V3.80
V8 series SYS PROG:version V2.280
TS2000 series SYS PROG:version V2.300
TS1000 series SYS PROG:version V2.300
TS1000Smart series SYS PROG:version V2.300
OCT 2019 Ver. 6.0.34.0
- V9 series SYS PROG:version V2.000, OS:version V3.80
V8 series SYS PROG:version V2.280
TS2000 series SYS PROG:version V2.300
TS1000 series SYS PROG:version V2.300
TS1000Smart series SYS PROG:version V2.300
-
V9/TS/V8 series: 追加PLC梯形图传送功能:
- FATEK AUTOMATION FACON - Rising pulse / falling pulse supported.
- Panasonic FP Series (RS232C / 422) (Ethernet UDP / IP, TCP / IP) FP0H added.
- Fuji Electric ALPHA7 (MODBUS RTU) supported.
- MITSUBISHI ELECTRIC QnH (A) series CPU supported.
- V9 series: USB camera supported.
- V9 series: Alarm Server - [Put msec information on time] option supported.
- V9 series: Recipe dialog box - Date and time display supported.
- V9 series: Additional General settings
- V9 series: Extended system devices for IP addresses of LAN2/WLAN added.
- V-SFT-6: Program conversion to V9 - New dialog box for Ethernet port conversion supported.
- V-SFT-6: Print and Rich Text Format output - Additional menu to output extended display area supported.
- V-SFT-6: Recipe - Extended BIN file edit function for Memory Card mode supported.
- V-SFT-6: Operability of the V-SFT-6 improved.
MAY 2019 Ver. 6.0.33.0
- V9 series SYS PROG: Version V1.900,OS:Version V3.50
V8 series SYS PROG:version V2.280
TS2000 series SYS PROG:version V2.280
TS1000 series SYS PROG:version V2.280
TS1000Smart series SYS PROG:version V2.280
MAY 2019 Ver. 6.0.32.0
- V9 series SYS PROG: Version V1.900,OS:Version V3.50
V8 series SYS PROG:version V2.280
TS2000 series SYS PROG:version V2.280
TS1000 series SYS PROG:version V2.280
TS1000Smart series SYS PROG:version V2.280
-
V9/TS/V8 series: 追加PLC梯形图传送功能:
- OMRON E5CC/E5EC/E5AC/E5DC/E5GC connection supported.
- NITTOKU ITS-HRW110 connection supported.
- YASKAWA DX200 (high-speed Ethernet) : file control command supported.
- Modbus slave (TCP/IP): Variable port number supported.
- V9 series: E-mailing with attachment file function supported.
- V9 series: Splash screen: visibility control of progress bar supported.
- V9 series: WLAN: Connection to an access point in stealth mode supported.
- V9 series: Additional General settings
- V9/TS/V8 series: Calendar display in the new era name "Reiwa" supported.
- V-SFT-6: "DEL_FILE" macro command supported.
- V-SFT-6: Operability of the V-SFT-6 improved.
JAN 2019 Ver. 6.0.31.0
- V9 series SYS PROG: Version V1.800,OS:Version V3.40
V8 series SYS PROG:version V2.270
TS2000 series SYS PROG:version V2.270
TS1000 series SYS PROG:version V2.270
TS1000Smart series SYS PROG:version V2.270
OCT 2018 Ver. 6.0.30.0
- V9 series SYS PROG: Version V1.800,OS:Version V3.40
V8 series SYS PROG:version V2.270
TS2000 series SYS PROG:version V2.270
TS1000 series SYS PROG:version V2.270
TS1000Smart series SYS PROG:version V2.270
-
V9/TS/V8 series: 追加PLC梯形图传送功能:
- IDEC MICRO Smart (Ethernet TCP/IP) supported.
- IDEC MICRO Smart connectable device added.
- OMRON NJ series (EtherNet/IP) PLC8Way and multiple station number designation supported.
- OMRON CJ2 Ethernet connection supported.
-
TS/V8 series: 追加PLC梯形图传送功能:
- FUJI SPB (N mode) & FLEX-PC CPU - PLC ladder transfer function supported.
- V9 series: Trend: Scaling display supported.
- V9 series: Switch: Storage viewer function supported.
- V9 series: Recipe: Improved display supported.
- V9 series: $u registers increased from 32K words to 64K words.
- V9 series: Additional General settings
- Disable the animation effect of the trend (history).
- Use VNC server function without user authentication
- Put a message with multiple lines in one cell in CSV created by alarm data.
- V9/TS/V8 series: Numerals & Character display: Values appears as asterisks on a screen.
- V-SFT-6: Additional tag import function for OMRON NJ and Allen-Bradley
- V-SFT-6: OMRON NJ: Tag export function supported.
- V-SFT-6: Operation log: Converting assigned device notations into item comments.
- V-SFT-6: Recipe list display has been improved.
- V-SFT-6: Operability of the V-SFT-6 improved.
AUG 2018 Ver. 6.0.29.0
- V9 series SYS PROG: Version V1.750,OS:Version V3.30
V8 series SYS PROG:version V2.260
TS2000 series SYS PROG:version V2.260
TS1000 series SYS PROG:version V2.260
TS1000Smart series SYS PROG:version V2.260
-
V9/TS/V8 series: 追加PLC梯形图传送功能:
- Extended specifications: IDEC - D register range expanded
- Extended specifications: SAIA - DB register supported
- V-SFT-6: Edit model selection: TS1000 Smart series added
- V-SFT-6: Importing Tags from Siemens TIA Portal Ver. 14 / Ver. 15 supported
JUN 2018 Ver. 6.0.28.0
- V9 series SYS PROG: Version V1.720,OS:Version V3.30
V8 series SYS PROG:version V2.260
TS2000 series SYS PROG:version V2.260
TS1000 series SYS PROG:version V2.260
-
V9/TS/V8 series: 追加PLC梯形图传送功能:
- MITSUBISHI ELECTRIC MR-J2S-*CL supported.
- V9 series: "Panasonic network camera" Additionally supported models
- BB-SW172A, BB-ST165A, BB-SP104W
- V9 series: "Local screen" Changes in the RGB adjustment screen
- V9 series: "European bitmap fonts" ISO code supported (V8-compatible)
- V-SFT-6: "View menu" OFF/ON status switching buttons added
- V-SFT-6: Screen program batch downloading (Ethernet)
- V-SFT-6: Improvements in Connection Device Selection dialog box
- V-SFT-6: "Tag database" Search function added
- V-SFT-6: "Switch" Lamp device setting added to Output Device menu
- V-SFT-6: "Multi Copy" Additional copy option
OCT 2017 Ver. 6.0.27.0
- V9 series SYS PROG: Version V1.600,OS:Version V3.10
V8 series SYS PROG:version V2.220
TS2000 series SYS PROG:version V2.250
TS1000 series SYS PROG:version V2.250
-
V9 series: 追加PLC梯形图传送功能:
- EtherCAT(CUR-09) supported.
- Telemecanique TSX Micro ladder transfer function supported.
- V9 series: Stroke font (V8 compatible) supported.
- V-SFT-6: Importing and exporting Quick Access Toolbar supported.
AUG 2017 Ver. 6.0.26.0
- V9 series SYS PROG: Version V1.550,OS:Version V3.00
V8 series SYS PROG:version V2.220
TS2000 series SYS PROG:version V2.240
TS1000 series SYS PROG:version V2.240
- V9 series: Extended security function
V9 series: CSV files for adding titles to sampling file (V8 compatible) reading function
V9 series: Add operation for Recipe CSV files supported
V9 series: $R, Internal devices for Recipe data transfer supported
V-SFT-6: Titles for Recipe data editing function
JUL 2017 Ver. 6.0.25.0
- V9 series SYS PROG: Version V1.470,OS:Version V2.90
V8 series SYS PROG:version V2.220
TS2000 series SYS PROG:version V2.240
TS1000 series SYS PROG:version V2.240
- TS2000 series: System program fixed.
TS1000 series: System program fixed.
JUN 2017 Ver. 6.0.24.0
- V9 series SYS PROG: Version V1.470,OS:Version V2.90
V8 series SYS PROG:version V2.220
TS2000 series SYS PROG:version V2.230
TS1000 series SYS PROG:version V2.230
MAY 2017 Ver. 6.0.23.0
- V9 series SYS PROG: Version V1.470,OS:Version V2.90
V8 series SYS PROG:version V2.220
TS2000 series SYS PROG:version V2.230
TS1000 series SYS PROG:version V2.230
-
V9/TS/V8 series: 追加PLC梯形图传送功能:
- Yaskawa Electric DX200(High Speed Ethernet) supported.
- High-Pressure Gas Industry R-BLT supported.
APR 2017 Ver. 6.0.22.0
- V9 series SYS PROG: Version V1.430,OS:Version V2.90
V8 series SYS PROG:version V2.220
TS2000 series SYS PROG:version V2.220
TS1000 series SYS PROG:version V2.220
-
V9/TS/V8 series: 追加PLC梯形图传送功能:
- WAGO %MW address range extended.
- PROFIBUS-DP Individual settings of the Input/Output Byte Counts Setting supported.
- Siemens S7 PROFIBUS-DP Individual settings of the Input/Output Byte Counts Setting supported.
- Hitachi HIDIC-S10(OPCN-1) supported.
- MITSUBISHI ELECTRIC MR-J4-*A supported.
- Fuji Electric MICREX-SX series SPF supported.
- V9 series: Remote Desktop function supported.
- V9 series: Area transparent of Trend display area supported.
- V9 series: PDF Viewer function enhanced.
- V9 series: Multi-line title in the CSV Format Setting of Alarm Server/Logging Server supported.
- V9 series: Individual device designation in the Transfer Device Setting of the Recipe Data supported.
- V9 series: Display items such as V8 Compatible in General Setting added.
- V9 series: SANEI ELECTRIC printer supported.
- V9 series: Specifications of Macro command SYS(RESTART) changed.
- V9 series: Multi-line display in Flowing Message Settings supported.
- Default settings for Use the monitoring function in VPN Setting changed.
- V9 series: Specifications of the Communication Setting changed.
- TS series: VNC server function added.
- V-SFT-6: Switch - Transparent switch function added.
- V-SFT-6: Q/I/M devices in importing Tags for Siemens TIA supported.
- V-SFT-6: Specifications of the string registration method in String table changed.
- V-SFT-6: Specifications of the Control Device in Overlap during V9 conversion changed.
- V-SFT-6: Specifications of the ON Grid in the Grid Setting changed.
DEC 2016 Ver. 6.0.21.0
- V9 series SYS PROG: Version V1.360,OS:Version V2.80
V8 series SYS PROG:version V2.190
TS2000 series SYS PROG:version V2.200
TS1000 series SYS PROG:version V2.190
-
V9/V8 series: 追加PLC梯形图传送功能:
- JTEKT:TOYOPUC-Nano(Ethernet) supported.
- FESTO:FEC Series supported.
- SAIA:PCD DataMode supported.
- V9 series: TELLUS and V-Server supported.
- V-SFT-6: TELLUS Ver.4 supported.
OCT 2016 Ver. 6.0.20.0 a
- V9 series SYS PROG: Version V1.310,OS:Version V2.70
V8 series SYS PROG:version V2.190
TS2000 series SYS PROG:version V2.190
TS1000 series SYS PROG:version V2.190
OCT 2016 Ver. 6.0.20.0
- V9 series SYS PROG: Version V1.310,OS:Version V2.70
- V9 series: System Program and OS fixed.
OCT 2016 Ver. 6.0.19.0
- V9 series SYS PROG: Version V1.300,OS:Version V2.60
- V8 series SYS PROG: Version V2.190
- TS2000 series SYS PROG: Version V2.190
- TS1000 series SYS PROG: Version V2.190
-
V9/V8 series: 追加PLC梯形图传送功能:
- OMRON NJ Series(EtherNet/IP) supported.
- Yaskawa Electric MP3000 Series supported.
- DELTA DVP-SE(MODBUS ASCII) supported.
- DELTA DVP-SE(MODBUS TCP/IP) supported.
- VPN additional functions (retry, connection condition $s1679)
JUL 2016 Ver. 6.0.18.0
- V9 series SYS PROG: Version V1.270,OS:Version V2.60
- V8 series SYS PROG: Version V2.170
- TS2000 series SYS PROG: Version V2.180
- TS1000 series SYS PROG: Version V2.170
- V9 series: System Program fixed.
- V9 series: System language display in accordance with multi-language setting supported.
JUL 2016 Ver. 6.0.17.0
- V9 series SYS PROG: Version V1.250,OS:Version V2.60
- V8 series SYS PROG: Version V2.170
- TS2000 series SYS PROG: Version V2.170
- TS1000 series SYS PROG: Version V2.170
-
V9/V8 series: 追加PLC梯形图传送功能:
- RKC REX-F9000(Standard Protocol)supported.
- Modbus slave(RTU) RS422 (4-wire) supported.
- Modbus slave(ASCII) RS422 (4-wire) supported.
- RS Automation X8 Series Offset designation of ST device changed.
- RS Automation X8 Series(Ethernet) Offset designation of ST device changed.
- V9 series: Web Machine Interface Cloud Data Service Ver. 1.0 supported.(Operation to be started in August 2016)
- V9 series: Web Machine Interface VPN unencryption communication setting supported.
- V9 series: GUR-01(RGB IN-1CH) remake supported.
- V9 series: Network printer supported.
- V9 series: Scroll function added.
- V-SFT-6: Associating a [*.V8] file with V-SFT-6 during installation supported.
JUN 2016 Ver. 6.0.16.0
- V9 series SYS PROG: Version V1.230,OS:Version V2.50
- TS2000 series SYS PROG: Version V2.160
-
V9/V8 series: 追加PLC梯形图传送功能:
- KEYENCE KZ/KV series CPU supported.
- Siemens S120 (Ethernet ISOTCP) supported.
- V9 series: Gothic font (V8 compatible) supported.
- TS series: TS2000 series supported.
- V-SFT-6: Selection environment - hiding other items than target select items supported.
APR 2016 Ver. 6.0.15.0
- V9 series SYS PROG: Version V1.210,OS:Version V2.40
- V8 series SYS PROG: Version V2.150
-
V9 series: 追加PLC梯形图传送功能:
- Siemens S7-300/400MPI Ladder Transfer Function supported.
-
V9/V8 series: 追加PLC梯形图传送功能:
- Yaskawa Electric MP3000 Series (Ethernet UDP/IP) supported.
- A&D AD4402(MODBUS RTU) supported.
- A&D AD4404(MODBUS RTU) supported.
- FUJI FRENIC-Mini (MODBUS RTU)(C2) supported.
- FUJI FRENIC Series (CPU) supported.
- FUJI FRENIC Series (CPU) Ladder Transfer Function supported.
- FATEK AUTOMATION FACON FB Series Ladder Transfer Function supported.
- KEYENCE KZ24/300 CPU supported.
- V9 series: Video / RGB unit "GUR-00", "GUR-10", and "GUR-11" supported.
- V9 series: Screen program transfer - TCP/IP communication supported.
- V9 series: DHCP server (WLAN port) supported.
- V9 series: Data transfer viewer supported.
- V9 series: Data transfer service - device designation of folder name / file name supported. Filter function supported.
- V9 series: Substitute function for Memory card mode (V8 compatible) supported.
- V9 series: Video / RGB-IN enlarge display (V8 compatible) supported.
- V9 series: Logging server and Alarm server - compatible $s regsiteres with buffering area supported.
- V9 series: SRAM capacity for Operation log function extended.
- V-SFT-6: Symbol import for Siemens TIA Portal supported.
- V-SFT-6: Microsoft Windows 10 supported.
- V-SFT-6: HEX designation for bit device of MITSUBISHI PLC device supported.
- V8 series: "GU-01","GU-10", and "GU-11" revised hardware supported.
JAN 2016 Ver. 6.0.14.0
- V9 series SYS PROG: Version V1.180,OS:Version V2.30
- V8 series SYS PROG: Version V2.130
-
V9/V8 series: 追加PLC梯形图传送功能:
- Yaskawa Electric MP3000 Series EXPANSION MEMOBUS(Ethernet) supported.
- Lenze ServoDrive9400(Ethernet TCP/IP) supported.
- Siemens S7-200 PPI Ladder Transfer Functio supported.
- V9 series: GD-80E/V609E compatibility supported.
- V9 series: DHCP client function supported.
- V-SFT-6: Speed up launching when opening a screen program supported.
NOV 2015 Ver. 6.0.13.0
- V9 series SYS PROG: Version V1.160,OS:Version V2.20
- V8 series SYS PROG: Version V2.130
-
V9/V8 series: 追加PLC梯形图传送功能:
- FUJI FRENIC-Ace (MODBUS RTU) supported.
- YOKOGAWA UT32A/35A(MODBUS RTU) supported.
- YOKOGAWA UT52A/55A(MODBUS RTU) supported.
- YOKOGAWA UT75A(MODBUS RTU) supported.
- V9 series: Path through function supported with external devices connected via LAN port.
- V9 series: XOR drawing mode (V8 compatible) supported with numeric data display, switches, and lamps.
OCT 2015 Ver. 6.0.12.0
- V9 series SYS PROG: Version V1.140,OS:Version V2.10
- V8 series SYS PROG: Version V2.130
-
V9/V8 series: 追加PLC梯形图传送功能:
- MITSUBISHI FX5U/5UC series supported.
- MITSUBISHI FX5U/5UC series (Ethernet) supported.
- MITSUBISHI FX3U/3GE series(Ethernet)supported.
- MITSUBISHI L series CPU supported.
- KEYENCE KV-7000 (Ethernet TCP/IP) supported.
- FUJI PXF(MODBUS RTU) supported.
- Azbil SDC15 supported.
- Azbil SDC25/26 supported.
- Azbil SDC45/46 supported.
-
V8 series: 追加PLC梯形图传送功能:
- YOKOGAWA μR10000/20000 (Ethernet TCP/IP) supported.
- V9 series: Animation Viewer supported.
- V9 series: PDF Viewer function addition.
- V9 series: Ladder Transfer Function:Flow Control supported (When MITSUBISHI A series CPU is selected)
- V-SFT-6: Display device address with zero suppress
JUL 2015 Ver. 6.0.11.0
- V9 series SYS PROG: Version V1.120,OS:Version V2.00
- V8 series SYS PROG: Version V2.090
-
V9 series: 追加PLC梯形图传送功能:
- YOKOGAWA μR10000/20000(Ethernet TCP/IP) supported.
-
V9/V8 series: 追加PLC梯形图传送功能:
- FUJI FRENIC-VG1(MODBUS RTU) supported.
- FUJI HFR-K1K supported.
- Azbil SDC45/46 supported.
- OMRON V680S(Ethernet TCP/IP) supported.
- V9 series: V9HDCOPY macro supports data save in JPEG format.
- V9 series: Data sheet printing: Saving a PDF file without time stamp supported.
- V9 series: Alarm parts (V8 compatible) supports scroll bar function.
- V9 series: Security function supports login/logout macro commands.
APR 2015 Ver. 6.0.9.0
- V9 series SYS PROG: Version V1.100,OS:Version V1.80
- V8 series SYS PROG: Version V2.090
-
V9 series: 追加PLC梯形图传送功能:
- -Communication units supported (CC-Link/PROFIBUS/DeviceNet) .
-
V9/V8 series: 追加PLC梯形图传送功能:
- Siemens S7-1200/1500(Ethernet ISOTCP) connection supported.
- RS Automation CSD5(MODBUS RTU) connection supported.
- RS Automation Moscon-F50(MODBUS RTU) connection supported.
- MITSUBISHI iQ-R series(Built-in Ethernet) connection supported.
- MITSUBISHI iQ-R seriles link connection supported.
- MITSUBISHI iQ-R series(Ethernet) connection supported.
- V9 series: Ladder monitor supported (FUJI)
- V9 series: Ethernet network table edit from the local screen supported.
- V9 series: Selectable font size supported with alarm display (V8 compatible), bit sampling (V8 compatible), and data sampling function.
MAY 2015 Ver. 6.0.10.0
- V9 series SYS PROG: Version V1.110,OS:Version V1.90
- V8 series SYS PROG: Version V2.090
- V9 series: System Program and OS fixed.
APR 2015 Ver. 6.0.9.0
- V9 series SYS PROG: Version V1.100,OS:Version V1.80
- V8 series SYS PROG: Version V2.090
-
V9 series: 追加PLC梯形图传送功能:
- -Communication units supported (CC-Link/PROFIBUS/DeviceNet) .
-
V9/V8 series: 追加PLC梯形图传送功能:
- Siemens S7-1200/1500(Ethernet ISOTCP) connection supported.
- RS Automation CSD5(MODBUS RTU) connection supported.
- RS Automation Moscon-F50(MODBUS RTU) connection supported.
- MITSUBISHI iQ-R series(Built-in Ethernet) connection supported.
- MITSUBISHI iQ-R seriles link connection supported.
- MITSUBISHI iQ-R series(Ethernet) connection supported.
- V9 series: Ladder monitor supported (FUJI)
- V9 series: Ethernet network table edit from the local screen supported.
- V9 series: Selectable font size supported with alarm display (V8 compatible), bit sampling (V8 compatible), and data sampling function.
MAR 2015 Ver. 6.0.8.0
- V9 series SYS PROG: Version V1.090,OS:Version V1.70
- V8 series SYS PROG: Version V2.090
-
V9/V8 series: 追加PLC梯形图传送功能:
- -Universal serial : Word count of write command increased.
- V-SFT-6: LogToCSV (CSV conversion tool for operation log data) : V9 data (*db) supported.
FEB 2015 Ver. 6.0.7.0
- V9 series SYS PROG: Version V1.080,OS:Version V1.60
- V8 series SYS PROG: Version V2.090
- V9 series: System Program fixed.
- V-SFT-6: Failure fixed.
FEB 2015 Ver. 6.0.6.0
- V9 series SYS PROG: Version V1.070,OS:Version V1.50
- V8 series SYS PROG: Version V2.080
-
V9 series: 追加PLC梯形图传送功能:
- Communication units supported (Ethernet/OPCN-1/Fl-Net) .
-
V9/V8 series: 追加PLC梯形图传送功能:
- FUJI ALPHA5 (MODBUS RTU) parameter range extended.
-
V8 series: 追加PLC梯形图传送功能:
- DELTA DVP series Multi-link2 Ethernet connections supported.
- V9 series: Video (1ch), RGB-IN (1ch), and RGB-OUT (1ch) supported.
JAN 2015 Ver. 6.0.5.0
- V9 series SYS PROG: Version V1.060,OS:Version V1.40
- V8 series SYS PROG: Version V2.080
-
V9/V8 series: 追加PLC梯形图传送功能:
- Modbus slave(ASCII) connection supported.
- TOSHIBA VF-S15 connection supported.
- TOSHIBA VF-MB1 connection supported.
- TOSHIBA VF-nC3 connection supported.
- Allen-Bradley Micro800 Controllers connection supported.
- Allen-Bradley Micro800 Controllers(Ethernet TCP/IP) connection supported.
-
V9 series: Printer type added.:
- PR201 Monochrome/Color supported.
- ESC/P Monochrome/Color supported.
- CBM292/293 supported.
- MR400 supported.
- V9 series: Trend: Background function supported.
- V9 series: Text table supported.
- V9 series: PDF viewer supported.
- V9 series: Entry: Direct function supported.
- V9 series: FTP client function supported.
- V9 series: Ladder monitor function supported. (MITSUBISHI/OMRON/YOKOGAWA)
- V-SFT-6: V9150/V9120/V907xW/V9060 added to edit model.
- V-SFT-6: V8 added to edit model.
- V-SFT-6: Comment edit function supported with Message edit.
OCT 2014 Ver. 6.0.4.0
- SYS PROG: Version V1.050,OS:Version V1.30
-
追加PLC梯形图传送功能:
- Multi-link connection supported.
- Multi-link2 Ethernet and 1:n Multi-link2 Ethernet connections supported.
- PLC ladder transfer function 3Way supported.
- Overlap - Specifying superimpose color supported.
- Switch - "Switching to Local Mode" function supported.
- Alarm Tracking (V8 compatible) - Time lag display supported.
- Animation function supported.
- Storage setting - Pattern, 3D parts, and Windows font supported.
- Line width specified by point supported.
- Operation log- Saving settings of sort, filter, search, and display settings supported.
- Recipe - semicolon (;) as CSV file separator supported.
- VNC server - System memory supported.
- VNC authentication screen - User-defined splash screen supported.
- General Settings - "Hide Check Screen" supported.(Check Screen = Data Loading)
- Rotate display of the "Check screen" supported.(Check Screen = Data Loading)
- V-SFT-6: Widows8.1 supported.
- V-SFT-6: File conversion from V7/V6/V4/GD80 to V9 supported.
- V-SFT-6: Pasting MS Office drawings on the software supported.
- V-SFT-6: "DXF file conversion" feature enhanced.
- V-SFT-6: GD-80E/V609E compatible setting - color batch change supported.
- Part frame fix supported with the parts other than switch/lamp.
- Macro GET_SMPL , SAMPLE supported with V9.
- CF Card Function(VCFAcs.DLL)supported.
SEP 2014 Ver. 6.0.3.0
- SYS PROG: Version V1.040,OS:Version V1.20
-
追加PLC梯形图传送功能:
- Monitor command supported.
[Supported model]
Panasonic: FP Series(RS232C/422),FP Series(Ethernet TCP/IP), FP Series(Ethernet UDP/IP),FP-X(Ethernet TCP/IP)
SAMSUNG: SECNET
RS OEMax: N7/NX Series(70/700/750/CCU)
- Multi-link2 (serial) supported.
- VPN function supported.
- Macro command compatible with V8 (SYS(GET_SMPL)) supported.
JUL 2014 Ver. 6.0.2.0
- SYS PROG: Version V1.030,OS:Version V1.10
-
追加PLC梯形图传送功能:
- FUJI:MICREX-F Tlink / MICREX-F Tlink V4 Compatible supported.
- FUJI:MICREX-F Tlink / MICREX-F Tlink V4 Compatible supported.
- FUJI:MICREX-SX(SX bus) supported.
- Modbus Slave(TCP/IP) supported.
- Ladder transfer function added.
- VPN function supported.
- Overlay display of trend graph supported.
- Storing messages into a storage supported.
- OS automatic upload function supported.
- Emulator supported.
- Recipe dialog function supported.
- V-SFT-6: High speed data transfer supported.
- V-SFT-6: MICREX-SX variable names cooperation supported.
- V-SFT-6: Chinese (simplified, traditional) and Korean supported (available with other languages than Japanese).
- V-SFT-6: Fixing 3D parts frame supported.
- V-SFT-6: Plate parts supported.
- V-SFT-6: Switch - accumulation function supported.