Smart Editor Improvement information

Smart Editor Ver.1.1.4.0 a → Ver.1.1.5.0 Date of Release 2026/10/15

◆Configuration Software
No. Item Description TS/V8 TS4000 V9 V10 X1 Correction
Ver.
26A0Z01 Switch output Fixed the defect: When [Number of Outputs] is set to 2 or more, and then the output device memory is [1] to [15], [Action] is set to [Word Operation], and [Operation Mode] is set to anything other than [Transfer] in the settings of a switch, [Operand Device] cannot be set to [Constant]. ● ● ● ● ● 1.1.5.0
26A0Z02 Graphic library Fixed the defects: “Text” cannot be placed on a graphic library. Parameters cannot be specified. ● ● ● ● ● 1.1.5.0
26A0Z03 Device memory map Fixed the defect: When comments are registered to all numbers on a device memory map and then a non-serial number is newly added, all comments thereafter are shifted. ● ● ● ● ● 1.1.5.0
26A0Z04 Macro settings Fixed the defect: When an open, close, or cycle macro is deleted in the [Macro Settings] and the screen program is saved and closed, it may not be possible to open the screen program again. ● ● ● ● ● 1.1.5.0
26A0Z05 Number of screens to display Fixed the defect: When the [Maximum number of screens to open] setting is enabled (with the limitation set to any number), if an overlap library or the like with the same number as a screen number that is not displayed is opened, the editor may be forcibly terminated if a different screen is newly opened. ● ● ● ● ● 1.1.5.0
26A0Z06 Number of screens to display Fixed the defect: When the [File] -> [Properties] -> [General] -> [Maximum number of screens to open] setting is set to “1” and a screen that is not displayed is opened from the [Project View] pane while the catalog or a form or view for item information is not opened, editing may become disabled. ● ● ● ● ● 1.1.5.0
26A0Z07 Changing connected devices Fixed the defect: When the Siemens S7 is changed to S7-300/400 (MPI, Ethernet ISOTCP, Ethernet TCP/IP PG Protocol), the DB address number may not be converted correctly. ● ● ● ● ● 1.1.5.0
26A0Z08 Changing the edit model Fixed the defect: When a V8 screen program or earlier is converted via [File] -> [Open] -> [Convert and open], the screen program may not be converted correctly. ● ● ● ● ● 1.1.5.0
26A0Z09 E-mail notification Fixed the defect: When using the e-mail notification function of the data transfer service, an attachment is not sent when sending an e-mail for the first time after turning the power on. ● ● ● ● 1.1.5.0
26A0Z10 Trend graphs Fixed the defect: When the link of trend graph parts is canceled, the display mode cannot be changed to real-time display. ● ● ● ● ● 1.1.5.0
26A0Z11 Moving parts Fixed the defect: Moving parts on a screen consecutively may forcibly terminate the editor. ● ● ● ● ● 1.1.5.0
26A0Z12 Selection of multiple parts Fixed the defect: When multiple parts are selected, the coordinates cannot be specified from the properties. ● ● ● ● ● 1.1.5.0
26A0Z13 Graphic library Fixed the defect: When a graphic library is placed as a part on the same graphic library number, the editor may be forcibly terminated upon an error check or when the placed graphic library is selected. ● ● ● ● ● 1.1.5.0
26A0Z14 Parts library Fixed the defect: When [Hide unregistered screen] is selected on the right-click menu of the [Screen List], the [Tool] -> [Search] -> [Parts Library] display is completely blank (white). ● ● ● ● ● 1.1.5.0
26A0Z15 Selecting multiple switches Fixed the defect: When multiple switches are selected and aligned using [Align] on the right-click menu, the device memory setting in the [Display Setting] of the switches is initialized. ● ● ● ● ● 1.1.5.0
26A0Z17 Forcible termination Fixed the defect: Smart Editor may be forcibly terminated when the following sequence of operations is performed.
1. Start Smart Editor (from the icon).
2. Maximize the display.
3. Switch to window display.
4. Press the small triangle mark on the left end to open the [Project View] pane.
● ● ● ● ● 1.1.5.0
26A0Z18 Macro blocks Fixed the defect: When a screen is edited with a macro block opened, the macro block may not be activated from the taskbar. ● ● ● ● ● 1.1.5.0
26A0Z19 Display environment settings Fixed the defect: The [Display Environment] window cannot be closed with the ESC key. ● ● ● ● ● 1.1.5.0
26A0Z20 Soft function switch settings Fixed the defect: When editing a TS1000S screen program, changes in the checked status of the [Hardware Settings] -> [Unit Settings] -> [Soft Function Switch Settings] -> [Display in the center with VGA size (640x480)] setting are not reflected to the opened screens. ● 1.1.5.0
26A0Z21 Modbus free format setting Fixed the defect: When a connected device is changed from an Azbil NX (Modbus RTU) to MODBUS RTU, the message “Communication parameters will be set to defaults.” is displayed. If “No” is selected at this time, the “Holding Register” and “Input Register” in the Modbus free format settings are set to “Library”, and communication is not possible in this state. ● ● ● ● ● 1.1.5.0
26A0Z22 Oriental Motor Fixed the defect: When an Oriental Motor device is connected with [Connection Mode] set to “1:1”, device memory settings for macros cause an error indicating that the argument is invalid. ● ● ● ● ● 1.1.5.0
26A0Z23 SX variable name cooperation Fixed the defect: When a variable name is used in specifying the [Output Device] of a switch on a screen program with SX variable name cooperation, changes cannot be saved when only the resource name has been changed. ● ● ● ● ● 1.1.5.0
26A0Z24 Alarm blocks Fixed the defect: The content of setting items displayed in [Control Device Setting] of alarm blocks and that displayed in the information popups differ. ● ● ● ● ● 1.1.5.0
26A0Z25 Korean display Fixed the defect: The word meaning “display” in “alarm history display” and “event history display” when the interface language is set to Korean is displayed in Japanese. ● ● ● ● ● 1.1.5.0
26A0Z26 Design properties pane Fixed the defect: When [Type] is set to [Select from catalogs] and [Part Type: Setting] is clicked on the [Design] properties pane, the [Design Selection] window is not displayed. ● ● ● ● ● 1.1.5.0
26A0Z27 Traditional Chinese menu Fixed the defect: When using Traditional Chinese, the items on the right-click menu displayed when multiple items are selected differ from those displayed on V-SFT-6. ● ● ● ● ● 1.1.5.0
26A0Z28 Simulator Fixed the defect: When using a PLC model which uses tags, the editor may be forcibly terminated when starting the Simulator. ● ● ● ● ● 1.1.5.0
26A0Z29 Trend graphs Fixed the defect: When device memory is used to specify the maximum and minimum values on a trend graph, the editor may be forcibly terminated. ● ● ● ● ● 1.1.5.0
26A0Z30 Forcible termination Fixed the defect: When using recipe macros on a screen program without recipe settings to write to MONITOUCH, save the screen program, change the edit model, print, or convert rich text, the editor may be forcibly terminated. ● ● ● ● ● 1.1.5.0
26A0Z31 Device memory search Fixed the defect: When a word lamp is placed and a device search is performed, the search result indicates that two words are occupied. ● ● ● ● ● 1.1.5.0
26A0Z32 Switches, lamps Fixed the defect: When multiple switches/lamps are selected while in the ON state, the status changes to the OFF state when the properties are displayed. ● ● ● ● ● 1.1.5.0
26A0Z33 Opening a screen program Fixed the defect: The editor may be forcibly terminated if a device memory map is displayed immediately after opening a screen program file. ● ● ● ● ● 1.1.5.0
26A0Z34 Alarm settings Fixed the defect: When device memory of a PLC that uses tags is specified in array format for [Minimum] and [Maximum] of the [Alarm Setting] for a numerical data display and then the decimal place setting is changed from “1” or higher to “0”, the device memory for [Minimum] and [Maximum] of the [Alarm Setting] may be changed inadvertently. ● ● ● ● ● 1.1.5.0
26A0Z35 Vulnerability Fixed the defect: The editor is forcibly terminated when an attempt is made to open an invalid screen program. (JVNVU #96549652) ● ● ● ● ● 1.1.5.0
26A0Z36 Overlap display Fixed the defect: When a screen program with multi-language settings has a keypad overlap placed from the settings of a numerical data display part, MONITOUCH may restart once the program is transferred. ● ● ● ● ● 1.1.5.0
26A0Z37 [Edit Model]: TELLUS Fixed the defect: When AutomationDirect’s “Direct LOGIC (Ethernet UDP/IP)” is selected as a PLC, the [Transfer Speed] setting in the [Properties] pane for the PLC is not displayed if the [Edit Model] is [TELLUS]. ● ● ● ● ● 1.1.5.0
26A0Z38 External characters, tiles Fixed the defect: The editor may be forcibly terminated when editing 16-dot or 32-dot external characters or tiles for an extended time. ● ● ● ● ● 1.1.5.0
26A0Z39 Character display Fixed the defect: When the device memory used for a character display is a tag, it is displayed as a double-word device memory address. ● ● ● ● ● 1.1.5.0
26A0Z40 PLC model change Fixed the defect: When the PLC model is changed from “QnH (Q) series (Ethernet)” to “iQ-R series (Ethernet)”, error 46 occurs on MONITOUCH upon transferring the changed screen program. ● ● ● ● ● 1.1.5.0
26A0Z41 Error check Fixed the defect: When the [Conversion] setting of a device memory address for a logging block is set to [Yes] and division is specified for the operation, an error indicating that the divisor is “0” occurs upon an error check. ● ● ● ● ● 1.1.5.0
26A0Z42 Display language change Fixed the defect: When the display language is changed immediately after opening a screen program and then an error check is performed, an error indicating that multiple overlaps exist may occur. ● ● ● ● ● 1.1.5.0
26A0Z43 Error check Fixed the defect: The state where only dummy words are registered in a device memory map cannot be detected by error check. ● ● ● ● ● 1.1.5.0

◆V10 series: System Program
No. Item Description Altered
Ver.
OS
Ver.
Correction
Ver.
26A0T01 Recipes Fixed the defect: When there are 10,000 or more records in the CSV file when attempting to load data from that file using the loading function for recipes, pressing [Cancel] or [Load] before the blue progress bar reaches the right end indicating completion may cause MONITOUCH to restart. 1.800 1.1.5.0
26A0T02 CSV/backup Fixed the defect: When [CSV/Backup Setting] for a logging server comprises [Drive for Output] set to [USB] and [Output timing] set to only [Upon storage removal], a CSV file is created when a screen program is transferred. 1.800 1.1.5.0
26A0T03 Graphic relay Fixed the defect: When using a graphic relay (“1 Graphic” type, rendering mode “XOR”), if an arrow with the same size and coordinates as an arrow on the base screen is created in the graphic library and this is displayed using the graphic relay, the arrow is displayed deviated from the arrow on the base screen. 1.800 1.1.5.0
26A0T04 Comment display Fixed the defect: When the show/hide setting is used for a comment display part, if the screen is changed over while the part is hidden and then the part is displayed by the specified device memory address, the comments are not displayed after the part is hidden and then displayed again. 1.800 1.1.5.0
26A0T05 Siemens S7-200 PPI Fixed the defect: A connection with the PLC sometimes cannot be established when the power is turned on. 1.90 1.1.5.0
26A0T06 VNC connection Fixed the defect: The V10 series unit restarts when Ultra VNC Viewer version 1.6.0.0 or later is used to access the unit from a PC. 1.90 1.1.5.0
26A0T07 Slider switch Fixed the defect: When PLC device memory is used to specify the minimum and maximum scale values of a slider switch, the switch does not function. 1.800 1.1.5.0
26A0T08 Security settings Fixed the defect: When the maximum of 32 users are registered in the security settings, the users registered from [SYSTEM] -> [Security] may disappear from the list, making addition, deletion, and editing impossible. 1.800 1.1.5.0
26A0T09 Splash screen Fixed the defect: When a PNG file with the same resolution as the V10 series unit is registered, the right and bottom of the image is clipped by 1 dot. 1.800 1.1.5.0
26A0T10 BRIGHT macro command Fixed the defect: When [CSV/Backup Setting] for a logging server comprises [Drive for Output] set to [USB] and [Output timing] set to [Upon storage removal], executing a BRIGHT macro command creates a CSV backup file. 1.800 1.1.5.0
26A0T11 USB flash drive Fixed the defect: A USB flash drive may not be recognized properly. 1.800 1.1.5.0
26A0T12 Ethernet communication Fixed the defect: When reading of an address that does not exist on a PLC is repeated during TCP/IP communication with that PLC, disconnection and reconnection may occur frequently, thereby inhibiting refreshing and changing of screens, and operations with respect to the PLC. 1.800 1.1.5.0
26A0T13 Panel meter Fixed the defect: When a negative value (e.g., -100) is set to the device memory for indicating the current value of a panel meter, the displayed value is “---.--” (indicating overflow) instead of “-1.00”. 1.800 1.1.5.0

◆V10 series: Communication Driver
No. Item Description Altered
Ver.
Correction
Ver.
26A0U01 SAIA PCD S-BUS (Ethernet) Fixed the defect: When a PLC is connected, the V10 series unit restarts. 1.500 1.1.5.0
26A0U02 RS Automation X8 series Fixed the defect: When a BMOV macro is set to transfer 480 words or more of N device memory, a communication error (time-out) occurs. X8_Xnet,tpf: 1.520
X8_Xnet_E.tpf: 1.510
1.1.5.0
26A0U03 Universal PROFIBUS-DP Fixed the defect: PROFIBUS communication is not always possible. 1.460 1.1.5.0
26A0U04 Ethernet type drivers Fixed the defect: When a communication error occurs with [Comm. Error Handling] set to [Disconnect] and [Use KeepAlive] set to [Yes], the V10 series unit may freeze or restart.
<Scope> Ethernet type drivers provideed with the following versions:
- V-SFT V6.2.11.0, Smart Editor V1.1.4.0 (released April 2026)
- V-SFT V6.2.11.0a, Smart Editor V1.1.4.0a (released June 2026)
- 1.1.5.0
26A0U05 Universal serial Fixed the defect: When a system update is performed with “Universal serial” as the communication driver, the setup error “The PLC model set in the screen program does not match the I/F driver.” may occur. 1.610 1.1.5.0

◆V9 series: System Program
No. Item Description Altered
Ver.
OS
Ver.
Correction
Ver.
26A0J01 Slider switch Fixed the defect: When PLC device memory is used to specify the minimum and maximum scale values of a slider switch, the switch does not function. 3.700 1.1.5.0
26A0J02 Security settings Fixed the defect: When the maximum of 32 users are registered in the security settings, the users registered from [SYSTEM] -> [Security] may disappear from the list, making addition, deletion, and editing impossible. 3.700 1.1.5.0
26A0J03 CSV/backup Fixed the defect: When [CSV/Backup Setting] for a logging server comprises [Drive for Output] set to [USB] and [Output timing] set to only [Upon storage removal], a CSV file is created when a screen program is transferred. 3.700 1.1.5.0
26A0J04 Graphic relay Fixed the defect: When using a graphic relay (“1 Graphic” type, rendering mode “XOR”), if an arrow with the same size and coordinates as an arrow on the base screen is created in the graphic library and this is displayed using the graphic relay, the arrow is displayed deviated from the arrow on the base screen. 3.700 1.1.5.0
26A0J05 Comment display Fixed the defect: When the show/hide setting is used for a comment display part, if the screen is changed over while the part is hidden and then the part is displayed by the specified device memory address, the comments are not displayed after the part is hidden and then displayed again. 3.700 1.1.5.0
26A0J06 Splash screen Fixed the defect: When a PNG file with the same resolution as the V10 series unit is registered, the right and bottom of the image is clipped by 1 dot. 3.700 1.1.5.0
26A0J07 BRIGHT macro command Fixed the defect: When [CSV/Backup Setting] for a logging server comprises [Drive for Output] set to [USB] and [Output timing] set to [Upon storage removal], executing a BRIGHT macro command creates a CSV backup file. 3.700 1.1.5.0
26A0J08 USB flash drive Fixed the defect: A USB flash drive may not be recognized properly. 3.700 1.1.5.0
26A0J09 Panel meter Fixed the defect: When a negative value (e.g., -100) is set to the device memory for indicating the current value of a panel meter, the displayed value is “---.--” (indicating overflow) instead of “-1.00”. 3.700 1.1.5.0

◆V9 series: Communication Driver
No. Item Description Altered
Ver.
Correction
Ver.
26A0K01 SAIA PCD S-BUS (Ethernet) Fixed the defect: When a PLC is connected, the V10 series unit restarts. 1.500 1.1.5.0
26A0K02 RS Automation X8 series Fixed the defect: When a BMOV macro is set to transfer 480 words or more of N device memory, a communication error (time-out) occurs. X8_Xnet,tpf: 1.520
X8_Xnet_E.tpf: 1.510
1.1.5.0
26A0K03 Universal PROFIBUS-DP Fixed the defect: PROFIBUS communication is not always possible. 1.460 1.1.5.0
26A0K04 Ethernet type drivers Fixed the defect: When a communication error occurs with [Comm. Error Handling] set to [Disconnect] and [Use KeepAlive] set to [Yes], the V10 series unit may freeze or restart.
<Scope> Ethernet type drivers provideed with the following versions:
- V-SFT V6.2.11.0, Smart Editor V1.1.4.0 (released April 2026)
- V-SFT V6.2.11.0a, Smart Editor V1.1.4.0a (released June 2026)
- 1.1.5.0
26A0K05 Universal serial Fixed the defect: When a system update is performed with “Universal serial” as the communication driver, the setup error “The PLC model set in the screen program does not match the I/F driver.” may occur. 1.610 1.1.5.0

◆TS4000 series: System Program
No. Item Description Altered
Ver.
OS
Ver.
Correction
Ver.
26A0b01 Splash screen Fixed the defect: When a PNG file with the same resolution as the V10 series unit is registered, the right and bottom of the image is clipped by 1 dot. 1.500 1.1.5.0
26A0b02 BRIGHT macro command Fixed the defect: When [CSV/Backup Setting] for a logging server comprises [Drive for Output] set to [USB] and [Output timing] set to [Upon storage removal], executing a BRIGHT macro command creates a CSV backup file. 1.500 1.1.5.0
26A0b03 USB flash drive Fixed the defect: A USB flash drive may not be recognized properly. 1.500 1.1.5.0
26A0b04 Internal storage Fixed the defect: When the TS4000 series unit is started with a USB flash drive connected, the setup error “Data in the internal storage (G) is corrupt.” may occur. 1.500 1.1.5.0
26A0b05 Logo display at startup Fixed the defect: The logo is not displayed upon startup. 1.30 1.1.5.0
26A0b06 Recipes Fixed the defect: When there are 10,000 or more records in the CSV file when attempting to load data from that file using the loading function for recipes, pressing [Cancel] or [Load] before the blue progress bar reaches the right end indicating completion may cause MONITOUCH to restart. 1.500 1.1.5.0
26A0b07 CSV/backup Fixed the defect: When [CSV/Backup Setting] for a logging server comprises [Drive for Output] set to [USB] and [Output timing] set to only [Upon storage removal], a CSV file is created when a screen program is transferred. 1.500 1.1.5.0
26A0b08 Graphic relay Fixed the defect: When using a graphic relay (“1 Graphic” type, rendering mode “XOR”), if an arrow with the same size and coordinates as an arrow on the base screen is created in the graphic library and this is displayed using the graphic relay, the arrow is displayed deviated from the arrow on the base screen. 1.500 1.1.5.0
26A0b09 Comment display Fixed the defect: When the show/hide setting is used for a comment display part, if the screen is changed over while the part is hidden and then the part is displayed by the specified device memory address, the comments are not displayed after the part is hidden and then displayed again. 1.500 1.1.5.0
26A0b10 Siemens S7-200 PPI Fixed the defect: A connection with the PLC sometimes cannot be established when the power is turned on. 1.30 1.1.5.0
Ethernet communication Item Fixed the defect: When reading of an address that does not exist on a PLC is repeated during TCP/IP communication with that PLC, disconnection and reconnection may occur frequently, thereby inhibiting refreshing and changing of screens, and operations with respect to the PLC. 1.500 1.1.5.0
26A0b12 Panel meter Fixed the defect: When a negative value (e.g., -100) is set to the device memory for indicating the current value of a panel meter, the displayed value is “---.--” (indicating overflow) instead of “-1.00”. 1.500 1.1.5.0

◆TS4000 series: Communication Driver
No. Item Description Altered
Ver.
Correction
Ver.
26A0c01 SAIA PCD S-BUS (Ethernet) Fixed the defect: When a PLC is connected, the V10 series unit restarts. 1.500 1.1.5.0
26A0c02 RS Automation X8 series Fixed the defect: When a BMOV macro is set to transfer 480 words or more of N device memory, a communication error (time-out) occurs. X8_Xnet,tpf: 1.520
X8_Xnet_E.tpf: 1.510
1.1.5.0
26A0c03 Ethernet type drivers Fixed the defect: When a communication error occurs with [Comm. Error Handling] set to [Disconnect] and [Use KeepAlive] set to [Yes], the V10 series unit may freeze or restart.
<Scope> Ethernet type drivers provideed with the following versions:
- V-SFT V6.2.11.0, Smart Editor V1.1.4.0 (released April 2026)
- V-SFT V6.2.11.0a, Smart Editor V1.1.4.0a (released June 2026)
- 1.1.5.0
26A0c04 Universal serial Fixed the defect: When a system update is performed with “Universal serial” as the communication driver, the setup error “The PLC model set in the screen program does not match the I/F driver.” may occur. 1.610 1.1.5.0

◆TS/V8 series: System Program
No. Item Description Altered
Ver.
Correction
Ver.
26A0F01 Screen program transfer Fixed the defect: When screen program transfer (send/receive) is repeated during communication with a PLC, the TS1000S series unit does not switch to Local mode and stays in RUN mode, and transfer cannot start.
Applicable PLC models:
- AutomationDirect Direct LOGIC or Direct LOGIC (K-Sequence)
- JTEKT (KOYO ELECTRONICS) SU/SG or SU/SG (K-Sequence)
TS1000S
2.480
1.1.5.0

◆TS/V8 series: Communication Driver
No. Item Description Altered
Ver.
Correction
Ver.
26A0G01 AutomationDirect Direct LOGIC, Direct LOGIC (K-Sequence),
JTEKT (KOYO ELECTRONICS) SU/SG, SU/SG (K-Sequence)
Fixed an issue where, when communicating with a PLC, repeatedly performing screen transfers (sending/receiving) would prevent the system from switching to the local mode screen-leaving it stuck on the RUN mode screen-and cause the transfer to fail to start. Koyo_GE.tpe: 1.030
KoyoKSeq.tpe: 1.090
1.1.5.0
26A0G02 SAIA PCD S-BUS (Ethernet) Fixed the defect: When a PLC is connected, the V10 series unit restarts. 1.070 1.1.5.0
26A0G03 RS Automation X8 series Fixed the defect: When a BMOV macro is set to transfer 480 words or more of N device memory, a communication error (time-out) occurs. X8_Xnet,tpf: 1.090
X8_Xnet_E.tpf: 1.080
1.1.5.0
26A0G04 Universal PROFIBUS-DP Fixed the defect: PROFIBUS communication is not always possible. 1.040 1.1.5.0

MONITOUCH