  3. Smart Editor Improvement information

Smart Editor Improvement information

Smart Editor Ver.1.1.2.0 → Ver.1.1.3.0 Date of Release 2025/11/28

◆V10 series: System Program
No. Item Description Altered
Ver.
Correction
Ver.
OS
Ver.
25B0T01 Scheduler Fixed the defect: After the date and time set in the scheduler function, the operation repeats despite being outside the specified date and time. 1.600 1.0.3.0

◆V9 series: System Program
No. Item Description Altered
Ver.
Correction
Ver.
OS
Ver.
25B0J01 Scheduler Fixed the defect: After the date and time set in the scheduler function, the operation repeats despite being outside the specified date and time. 3.500 1.1.3.0
25B0J02 Video player Fixed the defect: Unable to play videos with the video player. 3.500 1.1.3.0

◆V9 series: Communication Driver
No. Item Description Altered
Ver.
Correction
Ver.
2540K01 BECKHOFF Tag ADS Protocol (Ethernet) Fixed the defect: When a tag of a PLC is used as the display device memory and a numerical data display with [Process cycle] set to low speed is placed on a screen, an error code may be displayed. 1.470 1.0.2.0
25A0K01 MITSUBISHI ELECTRIC FX5U/5UC series (Ethernet) Fixed the defect: Among special unit buffer memory, when the following two device memory addresses are monitored using numerical data displays, system error 40 occurs.
- U003\G01002
- U004\G01002
1.710 1.1.1.0

◆TS/V8 series: System Program
No. Item Description Altered
Ver.
Correction
Ver.
2540F01 Screen program transfer Fixed the defect: Screen program transfer is not possible via Ethernet TCP/IP for the TS2060i. TS:2.450 1.0.2.0
2540F02 N-state lamp Fixed the defect: When a screen program with an N-state lamp with conditions that use device memory addresses that do not exist (cannot be recognized) is transferred to the TS1000 Smart, rebooting occurs repeatedly. TS:2.450 1.0.2.0

◆TS/V8 series: Communication Driver
No. Item Description Altered
Ver.
Correction
Ver.
2540G01 BECKHOFF Tag ADS Protocol (Ethernet) Fixed the defect: When a tag of a PLC is used as the display device memory and a numerical data display with [Process cycle] set to low speed is placed on a screen, an error code may be displayed. 1.060 1.0.2.0
2540G01 BECKHOFF Tag ADS Protocol (Ethernet) Fixed the defect: When a tag of a PLC is used as the display device memory and a numerical data display with [Process cycle] set to low speed is placed on a screen, an error code may be displayed. 1.060 1.0.2.0

◆V10 series: Communication Driver
No. Item Description Altered
Ver.
Correction
Ver.
2540U01 BECKHOFF Tag ADS Protocol (Ethernet) Fixed the defect: When a tag of a PLC is used as the display device memory and a numerical data display with [Process cycle] set to low speed is placed on a screen, an error code may be displayed. 1.470 1.0.2.0
2540U01 Barcode Fixed the defect: When the device memory of a PLC connected via Ethernet is used as the interface device memory of a barcode reader, a link down error may occur when the power is turned ON. 1.500 1.0.2.0