| TELLUS Ver. 5 |
| Ver.5.0.5.0 a → Ver.5.0.6.0 | Date of Release | 2026/11/16 |
| No. | Item | Description | Altered Ver. |
Correction Ver. |
|---|---|---|---|---|
| 26B0X01 | Improvement of vulnerability | The message concerning administrator privileges displayed at the beginning of installation is changed. | - | 5.0.6.0 |
| 26B0X02 | Improvement of vulnerability | Fixed the defect: When a corrupted V9 screen program is opened using TELLUS Ver. 4 or Ver. 5, the application is terminated due to an error. (JVNVU #97628215) | - | 5.0.6.0 |
| 26B0X03 | Windows tablet | Fixed the defect: When TELLUS Ver. 5 is started on a Windows tablet, chattering may occur upon touch operations of an entry keypad, resulting in a character being input twice. | - | 5.0.6.0 |
| 26B0X04 | Panel meter | Fixed the defect: When a negative value (e.g., -100) is set to the device memory for indicating the current value of a panel meter, the displayed value is “---.--” (indicating overflow) instead of “-1.00”. | - | 5.0.6.0 |
| 26B0X05 | Option Settings | Fixed the defect: When creating a shortcut with [Generate folder at] set to anywhere other than the [Default Position] in the [Option] settings, the “Settings” folder alone is created in the default location (the working folder in the same hierarchy as the screen program data). | - | 5.0.6.0 |
| 26B0X06 | Option Settings | Fixed the defect: When the [Show Toolbar] checkbox is deselected in the [Option] settings and a 800x600 resolution screen program is started, selecting [Resize Screen] in the menu extends the screen downward from 800x600. | - | 5.0.6.0 |
| 26B0X07 | Graphic relay | Fixed the defect: When using a graphic relay (“1 Graphic” type, rendering mode “XOR”), if an arrow with the same size and coordinates as an arrow on the base screen is created in the graphic library and this is displayed using the graphic relay, the arrow is displayed deviated from the arrow on the base screen. | - | 5.0.6.0 |
| 26B0X08 | Comment display | Fixed the defect: When the show/hide setting is used for a comment display part, if the screen is changed over while the part is hidden and then the part is displayed by the specified device memory address, the comments are not displayed after the part is hidden and then displayed again. | - | 5.0.6.0 |
| 26B0X09 | Slider switch | Fixed the defect: When PLC device memory is used to specify the minimum and maximum scale values of a slider switch, the switch does not function. | - | 5.0.6.0 |
| 26B0X10 | Security settings | Fixed the defect: When the maximum of 32 users are registered in the security settings, the users registered from [SYSTEM] -> [Security] may disappear from the list, making addition, deletion, and editing impossible. | - | 5.0.6.0 |
| 26B0X11 | Splash screen | Fixed the defect: When a PNG file with the same resolution as the V10 series unit is registered, the right and bottom of the image is clipped by 1 dot. | - | 5.0.6.0 |
| 26B0Y01 | Ethernet type drivers | Fixed the defect: When a communication error occurs with [Comm. Error Handling] set to [Disconnect] and [Use KeepAlive] set to [Yes], the V10 series unit may freeze or restart. <Scope> Ethernet type drivers provideed with the following versions: ・TELLUS V5.0.5.0(released May 2026) |
- | 5.0.6.0 |
| 26B0Y02 | SAIA PCD S-BUS (Ethernet) |
Fixed the defect: When a PLC is connected, the V10 series unit restarts. | 1.500 | 5.0.6.0 |
| 26B0Y03 | RS Automation X8 series |
Fixed the defect: When a BMOV macro is set to transfer 480 words or more of N device memory, a communication error (time-out) occurs. ・X8_Xnet ・X8_Xnet_E |
1.520 1.510 |
5.0.6.0 |
| TELLUS Ver. 4 / Ver. 3 |
| Ver.4.0.26.0 a → Ver.4.0.27.0 | Date of Release | 2026/11/16 |
| No. | Item | Description | Altered Ver. |
Correction Ver. |
|---|---|---|---|---|
| 26B0Q01 | Improvement of vulnerability | The message concerning administrator privileges displayed at the beginning of installation is changed. | - | 4.0.27.0 |
| 26B0Q02 | Improvement of vulnerability | Fixed the defect: When a corrupted V9 screen program is opened using TELLUS Ver. 4 or Ver. 5, the application is terminated due to an error. (JVNVU #97628215) | - | 4.0.27.0 |
| 26B0Q03 | Panel meter | Fixed the defect: When a negative value (e.g., -100) is set to the device memory for indicating the current value of a panel meter, the displayed value is “---.--” (indicating overflow) instead of “-1.00”. | - | 4.0.27.0 |
| 26B0Q04 | Slider switch | Fixed the defect: When PLC device memory is used to specify the minimum and maximum scale values of a slider switch, the switch does not function. | - | 4.0.27.0 |
| 26B0Q05 | Security settings | Fixed the defect: When the maximum of 32 users are registered in the security settings, the users registered from [SYSTEM] -> [Security] may disappear from the list, making addition, deletion, and editing impossible. | - | 4.0.27.0 |
| 26B0Q06 | Graphic relay | Fixed the defect: When using a graphic relay (“1 Graphic” type, rendering mode “XOR”), if an arrow with the same size and coordinates as an arrow on the base screen is created in the graphic library and this is displayed using the graphic relay, the arrow is displayed deviated from the arrow on the base screen. | - | 4.0.27.0 |
| 26B0Q07 | Comment display | Fixed the defect: When the show/hide setting is used for a comment display part, if the screen is changed over while the part is hidden and then the part is displayed by the specified device memory address, the comments are not displayed after the part is hidden and then displayed again. | - | 4.0.27.0 |
| 26B0Q08 | Splash screen | Fixed the defect: When a PNG file with the same resolution as the V10 series unit is registered, the right and bottom of the image is clipped by 1 dot. | - | 4.0.27.0 |
| 26B0R01 | Ethernet type drivers | Fixed the defect: When a communication error occurs with [Comm. Error Handling] set to [Disconnect] and [Use KeepAlive] set to [Yes], the V10 series unit may freeze or restart. <Scope> Ethernet type drivers provideed with the following versions: ・TELLUS V4.0.26.0(released May 2026) |
- | 4.0.27.0 |
| 26B0R02 | SAIA PCD S-BUS (Ethernet) |
Fixed the defect: When a PLC is connected, the V10 series unit restarts. | - | 4.0.27.0 |
| 26B0R03 | RS Automation X8 series |
Fixed the defect: When a BMOV macro is set to transfer 480 words or more of N device memory, a communication error (time-out) occurs. ・X8_Xnet ・X8_Xnet_E |
1.520 1.510 |
4.0.27.0 |
| V-Server |
| Ver.5.0.5.0 a → Ver.5.0.6.0 | Date of Release | 2026/11/16 |
| No. | Item | Description | Altered Ver. |
Correction Ver. |
|---|---|---|---|---|
| 26B0S01 | Improvement of vulnerability | The message concerning administrator privileges displayed at the beginning of installation is changed. | - | 5.0.6.0 |
| 26B0S02 | File reading | Fixed the defect: When [File Reading] of the [Storage Info] function of V-Server is executed, a specified file cannot be read if two-byte characters are used in the filename. | - | 5.0.6.0 |
| 26B0S03 | Screen program export | Fixed the defect: When a screen program of 10 MB or larger is exported using V-Server, an error indicating insufficient memory may be displayed. | - | 5.0.6.0 |
| 26B0S04 | Alarm history | Fixed the defect: When reading alarms using V-Server, the read content may differ from the messages in the actual alarm record displayed on the V10 series unit. | - | 5.0.6.0 |